Megol Getriebeoel CLP 100

EP lubricants with outstanding lubricating and wear protection properties. Produced from high quality base oils and most modern sulphur-phosphorus-additives. Suited for use in industrial gears, roller-and plain bearings with high pressure loads, also especially for large plants with circulation system lubrication
Approvals / Specificaions:lube oil DIN 51517 - CLP 100
Characteristic data |
- |
- |
approx. values |
ISO viscosity class |
DIN 51519 |
¡¡ |
VG100 |
Viscosity at 0¡ãC |
DIN 51562 |
mm2/s |
1900 |
Viscosity at 40¡ãC |
DIN 51562 |
mm2/s |
105 |
Viscosity at 100¡ãC |
DIN 51562 |
mm2/s |
11,6 |
Viscosity index |
DIN ISO 2909 |
¡¡ |
97 |
Density at 15¡ãC |
DIN 51757 |
kg/m3 |
890 |
Flash point |
DIN ISO 2592 |
¡ãC |
240 |
Pour point |
DIN ISO 3016 |
¡ãC |
-24 |
Air separation capacity / 50¡ãC |
DIN 51381 |
min. |
5 |
De-emulsifying capacity / 54¡ãC |
DIN 51599 |
min. |
15 |
Ash, oxide |
DIN EN 7 |
g/100 g |
0,03 |
Ash, sulphate |
Din 51759 |
g/100 g |
0,04 |
Content of asphaltenes |
DIN 51595 |
g/100 g |
m.n.n.*) |
Content of undissolved substances |
DIN 51592 |
g/100 g |
m.n.n.*) |
Water content |
DIN ISO 3733 |
g/100 g |
m.n.n.*) |
Neutralisation index, acid |
DIN 51558 Part 1 |
mg KOH/g |
0,5 |
Corrosive effect on steel |
DIN 51585 |
degree of corrosion |
0-B |
Corrosive effect on copper |
DIN 51759 |
degree of corrosion |
1-125 A3 |
Ageing properties |
¡¡ |
¡¡ |
¡¡ |
Increase of viscosity |
DIN 51586 |
% |
1,0 |
Precipitate number |
DIN 51586 |
ml |
<0,05 |
Neutralisation index after 1000 h |
DIN 51587 |
mg KOH/g |
<2,0 |
Timken test |
SEB 181302 |
- |
- |
Wear under a load of |
- |
- |
- |
43lbs after 10 min |
- |
mg |
<4.0 |
Accepted load |
- |
lbs |
60 |
Foaming properties |
DIN 51566 |
¡¡ |
S1B-0/0 |
|
|
|
S2B-0/0 |
¡¡ |
|
|
S3B-0/0 |
Properties against sealing material |
¡¡ |
¡¡ |
¡¡ |
SRE-NBR 1 pursuant to |
¡¡ |
¡¡ |
¡¡ |
DIN 53538 Part 3 after |
Change in volume |
%-by-vol. |
+4 |
7 days at 100¡ãC |
Change in hardness |
Shore |
-1,5 |
FZG-gear test, short |
- |
- |
|
Normal-test A/16,3/90 |
DIN 51354 part 2 |
- |
>12 |
- |
Failure load level |
mg/KWh |
<0,27 |
- |
Special weight change |
- |
- |
*) m.n.n. = Quantity not detectable |
¡¡ |
¡¡ |
¡¡ |
|
|